Rockhampton Girls Grammar School
Asbestos Management Plan & ACM Registers

← All buildings

Building 17 — Heritage Playshed

Building Documents

2024 Asbestos Register — Heritage Playshed (Building 17)

2024 · Environics
Open

Clearance Certificate 201-089 — Heritage Playshed

PAYNTERS · 29 Aug 2021
Open

Clearance Certificate 201-104-1 — Heritage Playshed

PAYNTERS · 9 Oct 2021
Open

Clearance Certificate Q101021LK — Heritage Playshed

PAYNTERS · 23 Oct 2021
Open
ACM present: 5 asbestos-containing items recorded for this building. Refer to the register below before any works.

Asbestos Register

Material / productLocationExtentResultConditionControl / recommendationSample ref
Vinyl floor tilesInterior: storerooms 5, 6, 7 & 8 and the Stationery Store24 m²ChrysotileFairNon-friable unless removed by abrasive means (floor grind after lifting).PF1
Wall sheeting & partition wallsInterior: walls of storerooms & room 8; former shop, canteen & dressing rooms; partition walls between rooms; infill panel north wall (NE closed storage); second-hand clothes room; all outer walls of store rooms. Sheeting runs to start of ceiling cavity; several walls are plaster or canite.65–85 m²ChrysotilePoorNon-friable. Condition poor to fair.PF2
External wall sheeting & cover stripsExterior: building walls120 m²ChrysotileFairNon-friable.PF4
Wall sheetingInterior: wall of western elevation of main room12 m²ChrysotileFairNon-friable. Sampled during 2024 inspections.S14
Wall sheetingInterior: wall adjacent to north entry12 m²ChrysotileFairNon-friable. Sampled during 2024 inspections.S15

Non-Asbestos Materials

Sampled non-asbestos materials for this building will be listed here once loaded from the Certificates of Analysis.