← All buildings
Building 24 — Jackson House
Building Documents
2024 Asbestos Register — Jackson House (Building 24)
2024 · Environics
OpenACM present: 2 asbestos-containing items recorded for this building. Refer to the register below before any works.
Asbestos Register
| Material / product | Location | Extent | Result | Condition | Control / recommendation | Sample ref |
| Vinyl floor tiles | Interior: fire escape stairwell at northern end. Walls & ceiling sheeting in same area tested — no asbestos detected. | >30 m² | Chrysotile | Fair | Non-friable unless removed by abrasive method (lift & grind concrete). | S11 |
| Soffits (presumed) | Exterior: uppermost level — unable to access (working at height restriction) | >30 m² | Presumed Chrysotile | Fair | Material of same appearance tested at Luck Building and found to contain chrysotile asbestos. | Presumed |
Non-Asbestos Materials
| Material / product | Location | Analysis result | Sample ref |
| Ceiling — open covered area | Exterior: ground floor, adjacent to library, western side (extensive modern renovations) | No asbestos detected | S04 · COHLABS CoA 24-4489 |
| Compressed cement sheeting | Attached to uncovered stairwell infrastructure | No asbestos detected | S07 · COHLABS CoA 24-4489 |
| Wall sheeting — fire cabinet | Interior: within fire cabinet, level one, hallway west | No asbestos detected | S08 · COHLABS CoA 24-4489 |
| Wall sheeting — fire cabinet | Interior: within fire cabinet, level one, hallway east | No asbestos detected | S09 · COHLABS CoA 24-4489 |
| Wall sheeting — store room | Interior: store room, level one (some synthetic mineral fibres detected) | No asbestos detected | S10 · COHLABS CoA 24-4489 |
| Wall sheeting — fire escape stairwell | Interior: within fire escape stairwell, northern end | No asbestos detected | S12 · COHLABS CoA 24-4489 |
| Ceiling sheeting — fire escape stairwell | Interior: within fire escape stairwell, northern end | No asbestos detected | S13 · COHLABS CoA 24-4489 |