Rockhampton Girls Grammar School
Asbestos Management Plan & ACM Registers

← All buildings

Building 11 — Grant

Building Documents

2024 Asbestos Register — Grant (Building 11)

2024 · Environics
Open
ACM present: 3 asbestos-containing items recorded for this building. Refer to the register below before any works.

Asbestos Register

Material / productLocationExtentResultConditionControl / recommendationSample ref
Vinyl floor tilesInterior: Art room, below the G1 class room>40 m²ChrysotileFairNon-friable unless removed by abrasive method (e.g. lift & grind concrete). Cracked tiles at centre of room — recommend removal during 2025 due to poor condition at centre.ENV 001 · COHLABS CoA 24-9180
Internal wall & ceiling sheetingInterior: fire escape stairwell, southern side of building>50 m²ChrysotileFairNon-friable. 2013 SLR report noted asbestos labels sighted.G5
Sunshades — fibrous sheeting (presumed)Exterior: sunshades on north, east & south sides — no access at surveyPresumed ACMFairPresumed to contain asbestos (no access). Western-side sunshades sampled and found free of asbestos.Presumed

Non-Asbestos Materials

Material / productLocationAnalysis resultSample ref
External ceiling sheetingExterior: covered walkway off the Dining – Lounge – LaundryNo asbestos fibre detectedP7
Fibrous sheeting — sunshades (sampled sides)Exterior: ground floor & level 1 sunshades, western side of buildingNo asbestos detectedP8